Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13677871

- Product Categories
- Friendly Links
Information Name: | Portable power analyzer recording / waveform analyzer records |
Published: | 2015-04-14 |
Validity: | 300 |
Specifications: | Instrument host / 1 station |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | WFLC-Ⅵ portable power analyzer recording / waveform analyzer records the Wuhan Electric Power Co., Ltd. Ming Branch of WFLC-Ⅵ portable power analyzer record (waveform recorder analyzer) can simultaneously capture 16 analog channels and eight switch inputs, and there are four switch output (relay node output) has a free graphical analysis, the combination of operations, RMS calculation, calculation of AC power, three-phase symmetry analysis, spectral analysis, harmonic analysis, correlation analysis curve, graphics editing, and phasor drawing functions. Products nickname WFLC-Ⅵ portable power record analyzer waveform recorder analyzer product parameters analog input: A total of 16 channels, including 10 channels has an electrical isolation, 6 way standard 10kv or 20mA (through a converter box to convert) signal without isolation (this 6-way The main consideration of various channel signal transmitter). Specific parameters are as follows: AC-DC high voltage isolation strong signal: 2 independent. Range is: 20V, 100V, 500V, 2000V (peak value for the exchange amount). Each has a filter (OFF, 1800Hz, 300Hz, 50Hz), acceptable 10mA signal. Measurement accuracy of 0.5%. Have the software automatically zero function. AC-DC high-voltage isolation weak signal: 2 independent. Range is divided into: 75mV, 10V, 100V, 500V (for exchange capacity of the peak). Each has a filter (OFF, 1800Hz, 300Hz, 50Hz). Measurement accuracy of 0.5%. Have the software automatically zero function. Frequency voltage mode into: 3-way independence. Range is 135V (measurement accuracy of 0.5%), recording a value of the exchange amount, but can be automatically converted to RMS and RMS AC waveform and its waveform can be displayed simultaneously. Frequency current mode into: 3-way independence. Range is 1A, 5A, 25A, 50A (measurement accuracy of 0.5%), recording a value of the exchange amount, but can be automatically converted to RMS, RMS AC waveform and its waveform can be displayed simultaneously. Ordinary AC-DC module into: 6 Road. Range is 10V or 20mA (through a converter box to convert), the measurement accuracy of 0.5%. Record values ??for the exchange amount or direct traffic exchange amount can be automatically converted to RMS and RMS AC waveform and its waveform can be displayed simultaneously. Above and the brightest into the mold has a top DC function using the software, that is to take the amount of deviation function. Switch input: 8. Using empty node input. Switch output: 4. Using empty node output, equivalent to the general programmable time relay. http://www.whgdmk.com/aspcms/product/2014-4-30/156.html Features http://www.whgdmk.com WFLC-Ⅵ portable power analyzer record four channels AC-DC high-voltage isolation with four different filters (no filter, filter harmonics above 1800Hz, filter harmonics above 300Hz, 50Hz filter out harmonics above) the user can select the appropriate filter according to the test situation. For output ripple voltage thyristor (eg exciter field voltage, generator rotor voltage, etc.) may be admitted to its DC part, to facilitate data analysis selectable sampling rate: 200Hz, 400Hz, 800Hz, 1600Hz, 3200Hz, 6400Hz per channel, collection capacity of up to 512KB, the computer automatically by date of recording test date, the use of continuous recording mode waveform, using a single set of data recording mode (can draw any curves recorded several channels), the total time recorded wave in memory Allow case optionally. WFLC-2 memory is 512KB, recorded wave maximum time the number of channels is determined by the sampling and the sampling frequency, the software can guarantee wave recording instrument does not exceed the capacity of the memory. Single recording: suitable for static data recording, the recording mode to manual. RMS average frequency voltage and current can be recorded directly measured traffic, calculated active P, reactive power Q, power angle (phase angle), the system (machine-side) frequency F, three-phase voltage and current average. |
Admin>>>
You are the 17983 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan Guo Ming Branch Electric Power Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 17983 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan Guo Ming Branch Electric Power Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility